The Bioresource and Energy Services team require non-intrusive tank capacity and sediment assessments of Anaerobic Digesters using Lithium chloride as a trace element to comply with Environmental Permitting (England & Wa…
les) Regulations 2016 implementing the Industrial Emissions Directive (IED) every 5 years, which takes an integrated approach to controlling pollution to air, water, and land from industrial activities. We require the supplier to develop methodology to determine the effective volume of an anaerobic
digester over a short period of testing time. The effective volume should be calculated from the lithium concentration once it reaches a steady and consistent level. The calculation for effective volume should be based on the dose of lithiu